Ballistics and Explosives
| Tested Materials / Products | Name of Test | Testing Method |
|---|---|---|
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test General Vibration | MIL-STD-810H Method 514.8 Procedure I Category 4 Category 7 Category 8 Category 9 Category 10 Category 12 Category 13 Category 14 Category 16 Category 17 Category 20 Category 22 Category 24 Category 5 (Procedure II) |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test General Vibration | MIL STD 810G (Change I) Method 514.7 Procedure I Category 4 Category 7 Category 8 Category 9 Category 10 Category 12 Category 13 Category 14 Category 16 Category 17 Category 20 Category 22 Category 24 Category 5 (Procedure II) |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test General Vibration | MIL STD 810G Method 514.6 Procedure I Category 4 Category 7 Category 8 Category 9 Category 10 Category 12 Category 13 Category 14 Category 16 Category 17 Category 20 Category 22 Category 24 Category 5 (Procedure II) |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test General Vibration |
MIL STD 810F Method 514.5 Procedure I Category 4 Category 7 Category 8 Category 9 Category 10 Category 12 Category 13 Category 14 Category 16 Category 17 Category 20 Category 22 Category 24 Category 5 (Procedure II) |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test | RTCA/DO-160G Section 8 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Tests Cold / Vibration Hot / Vibration |
TS EN 60068-2-6 EN 60068-2-6 EN 60068-2-64 EN 60068-2-50 EN 60068-2-51 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Shock Test |
MIL-STD-810G (Change I) Method 516.7 Procedure I Procedure II Procedure IV Procedure VI |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Shock Test |
MIL-STD-810G Method 516.6 Procedure I Procedure II Procedure IV Procedure VI |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Shock Test |
MIL-STD-810F Method 516.5 Procedure I Procedure II Procedure IV Procedure VI |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Shock Test | RTCA/DO-160G Section 7 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Shock Test |
EN 60068-2-27 EN 60068-2-29 EN 60068-2-31 EN 60068-2-53 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Solar Radiation Test Cycling Steady State Dimensions: 950mm x 950mm x 950mm 5000mmx3000mmx2500mm Temperature: +200°C Humidity: Maximum 98% |
MIL-STD-810G (Change I) Method 505.6 Procedure I Procedure II |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Solar Radiation Test Cycling Steady State Dimensions: 950mm x 950mm x 950mm 5000mmx3000mmx2500mm Temperature: +200°C Humidity: Maximum 98% |
MIL-STD-810G Method 505.5 Procedure I Procedure II |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Solar Radiation Test Cycling Steady State Dimensions: 950mm x 950mm x 950mm 5000mmx3000mmx2500mm Temperature: +200°C Humidity: Maximum 98% |
MIL-STD-810F Method 505.4 Procedure I Procedure II |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Solar Radiation Test Cycling Steady State Dimensions: 950mm x 950mm x 950mm 5000mmx3000mmx2500mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
TS EN 60068-2-5 EN 60068-2-5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Solar Radiation Test Cycling Steady State Dimensions: 950mm x 950mm x 950mm 5000mmx3000mmx2500mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
EN ISO 4892-1 EN ISO 4892-2 |
| Torpedoes and Subsystems |
Low Temperature Test Dimensions: 870mmx1000mmx780mm 2000mmx1500mmx1500mm 5000mmx3000mmx2500mm 400mmx500mmx400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL T 18404 |
| Torpedoes and Subsystems |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mmx1500mmx1500mm 5000mmx3000mmx2500mm 400mmx500mmx400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL T 18404 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL-STD-810H Method 501.7 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G (Change I) Method 501.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: +200°C Humidity: Maximum 98% |
MIL STD 810G Method 501.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810F Method 501.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test – Temperature and Altitude – Temperature Variation Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
RTCA/DO-160G Section 4.0 Section 5.0 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
NATO AECTP 300 Method 302 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
MIL STD 810H Method 510.7 /P2 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
High Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm 510mm x 510mm x 535mm (+1000°C) Temperature: -70°C / +200°C Humidity: Maximum 98% |
EN 60068-2-2 EN 60068-2-30 EN 60068-2-78 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
MIL STD 810G (Change I) Method 510.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Low Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810H Method 502.7 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
MIL STD 810G Method 510.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Low Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G (Change I) Method 502.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
MIL STD 810F Method 510.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Low Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G Method 502.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
NATO AECTP 300 Method 313 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Low Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810F Method 502.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
RTCA/DO-160G Section 12 |
| Torpedoes and Subsystems |
Sand and Dust Test Dimensions: Cabin 1: 1000 x 1000 x 1000 mm Cabin 2: 1250 x 1250 x 5000 mm Cabin 3: 2000 x 2000 x 1600 mm Cabin 4: 3000 x 3000 x 2800 mm |
MIL T 18404 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Low Temperature Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
EN 60068-2-1 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Rain Test |
MIL STD 810G (Change I) Method 506.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Rain Test |
MIL STD 810G Method 506.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810H Method 507.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Rain Test |
MIL STD 810F Method 506.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G (Change I) Method 507.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Waterproofness Test |
RTCA/DO-160G Section 10 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G Method 507.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Immersion Test |
MIL STD 810G (Change I) Method 512.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810F Method 507.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Immersion Test |
MIL STD 810G Method 512.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Immersion Test |
MIL STD 810F Method 512.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
RTCA/DO-160G Section 6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Humidity Test – Humid Heat Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
NATO AECTP 300 Method 306 |
| Torpedoes and Subsystems |
Humidity Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL T 18404 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810H Method 503.7 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G (Change I) Method 503.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810G Method 503.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Earthquake Vibration and Shock Test | IEC 60721-2-6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
MIL STD 810F Method 503.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
EN 60068-2-14 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature Shock Test Dimensions: 870mm x 1000mm x 780mm 2000mm x 1500mm x 1500mm 5000mm x 3000mm x 2500mm 400mm x 500mm x 400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
NATO AECTP 300 Method 304 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Climatic Sequence Test Dimensions: 870mm x 1000mm x 780mm 2000mmx1500mmx1500mm 5000mmx3000mmx2500mm 400mmx500mmx400mm Temperature: -70°C / +200°C Humidity: Maximum 98% |
EN 60068-2-61 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Fog Test | MIL-STD-810G (Change I) Method 509.6 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Fog Test | MIL-STD-810G Method 509.5 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Fog Test | MIL-STD-810F Method 509.4 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Fog Test | RTCA/DO-160G Section 14 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Mist |
TS 2093 EN 60068-2-11 EN 60068-2-52 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Spray (Fog) Test | ASTM B117 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Salt Spray Tests | ISO 9227 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Icing / Freezing Test Freeze/Thaw Test |
MIL STD 810G (Change I) Method 521.4 Method 524.1 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Icing/Freezing Test Freeze /Thaw Test |
MIL STD 810G Method 521.3 Method 524.0 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Icing Test |
RTCA/DO-160G Section 24 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature, Humidity, Vibration and Altitude Test Excluded clauses: Altitude |
MIL STD 810G (Change I) Method 520.4 Excluded clauses: Sub clause: 2.2.3.2 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature, Humidity, Vibration and Altitude Test Excluded clauses: Altitude |
MIL STD 810G Method 520.3 Excluded clauses: Sub clause: 2.2.3.2 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products |
Temperature, Humidity, Vibration and Altitude Test Excluded clauses: Altitude |
MIL STD 810F Method 520.2 Excluded clauses: Sub clause: 2.2.3.2 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Temperature, Humidity, Vibration Test | EN 60068-2-53 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment Other Civilian Products | Vibration Test |
MIL-STD-167-1A Type I and Type II |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment and Other Civilian Products | Contamination by Fluids |
MIL-STD-810F Method 504.0 MIL-STD-810G Method 504.1 MIL-STD-810G w/Change I Method 504.2 MIL-STD-810H Method 504.3 |
| Military Equipment and Other Civilian Products | Fluids Susceptibility / Contamination by Fluids |
RTCA/DO-160G Section 11 NATO AECTP 300 Metod 314 EN 60068-2-74 |
| Mechanical, Electrical, Electronic Systems and Subsystems Military Equipment and Other Civilian Products | Fire, Flammability / Resistance to Fire |
RTCA/DO-160G Section 26 Category A Category B Category C ISO 2685 |
Mechanical Products
| Tested Materials / Products | Name of Test | Testing Method (National, International Standards, In-house Methods) |
|---|---|---|
| Lifts, Safety Components for Lifts - Landing and car door locking devices | Testing of landing and car door locking devices | TS EN 81-50 Clause 5.2 |
| Lifts, Safety Components for Lifts - Safety gear | Testing of safety gear | TS EN 81-50 Clause 5.3 |
| Lifts, Safety Components for Lifts - Overspeed governors | Testing of overspeed governors | TS EN 81-50 Clause 5.4 |
| Lifts, Safety Components for Lifts - Buffers | Testing of buffers | TS EN 81-50 Clause 5.5 |
| Lifts, Safety Components for Lifts - Unintended car movement protection means | Testing of unintended car movement protection means | TS EN 81-50 Clause 5.8 |
| Lifts, Safety Components for Lifts - Safety circuits containing electronic components and/or programmable electronic systems (PESSRAL) | Testing of safety circuits containing electronic components and/or programmable electronic systems |
EN 81-50 Clause 5.6 Excluded Clauses: 5.6.1.3 |
Electrical, Electronic and IT Products and Devices
| Tested Materials / Products | Name of Test | Testing Method (National, International Standards, In-house Methods) |
|---|---|---|
| Low-voltage switchgear and controlgear |
Low-voltage switchgear and controlgear - Part 1: General rules Product Information Normal service, mounting and transport conditions Clearances and creepage distances Actuator Indication of the contact position Terminals Additional requirements for equipment provided with a neutral pole Provisions for protective earthing Dedicated enclosures for equipment Power-frequency or DC withstand voltage of the main, auxiliary and control circuits Operational performance Durability Leakage currents of equipment suitable for isolation Test of materials to abnormal heat and fire Enclosures for equipment (Annex C) Excluded Clauses: IP X1, IP X2, and IP X9 Tests of mechanical strength of terminals Excluded Clauses: ≤10N.m and 9.2.5.3 Flexion test Pull-out test Temperature-rise Dielectric properties |
EN IEC 60947-1 Sub-clause 6 Sub-clause 7 Sub-clause 8.1.4 Sub-clause 8.1.5 Sub-clause 8.1.6 Sub-clause 8.1.8 Sub-clause 8.1.9 Sub-clause 8.1.10 Sub-clause 8.1.11 Sub-clause 8.2.3.3 Sub-clause 8.2.4.2 Sub-clause 8.2.4.3 Sub-clause 8.2.7 Sub-clause 9.2.2 Sub-clause 9.2.4 (Annex C) Excluded Clauses: IP X1, IP X2, and IP X9 Sub-clause 9.2.5 Excluded Clauses: ≤10N.m and 9.2.5.3 Flexion test Sub-clause 9.3.3.3 Sub-clause 9.3.3.4 |
| Low-voltage switchgear and controlgear |
Low-voltage switchgear and controlgear – Part 5-1: Control circuit devices and switching elements –
Electromechanical control circuit devices Product Information Normal service, mounting and transport conditions Clearances and creepage distances Dielectric properties (Max 5 kV) Durability Tests of mechanical strength of terminals Pull-out test Verification of actuating force (or torque) Verification of limitation of rotation (of a rotary switch) Temperature-rise Making and breaking capacities of switching elements under normal conditions (Max 30A, 260VAC) Making and breaking capacities of switching elements under abnormal conditions (Max 30A, 260VAC) Annex C (Special tests – Durability tests) (Max 30A, 260VAC) |
EN IEC 60947-5-1 Sub-clause 6 Sub-clause 7 Sub-clause 8.1.4 Sub-clause 8.2.3 Sub-clause 8.2.4.3 Sub-clause 9.2.5.2 Sub-clause 9.2.5.4 Sub-clause 9.2.6 Sub-clause 9.2.7 Sub-clause 9.3.3.3 Sub-clause 9.3.3.4 Sub-clause 9.3.3.5.3 Sub-clause 9.3.3.5.4 Annex C |
| Low-voltage switchgear and controlgear |
Low-voltage switchgear and controlgear – Part 4-1: Contactors and motor-starters –
Electromechanical contactors and motor-starters Dielectric Properties (Max 5 kV) |
EN IEC 60947-4-1 Sub-clause 9.3.3.4 |
| Final Product | Fire hazard testing – Part 10-2: Abnormal heat – Ball pressure test method |
TS EN 60695-10-2 EN 60695-10-2 IEC 60695-10-2 |
| Final Product | Fire hazard testing – Part 11-5: Test flames – Needle-flame test method – Apparatus, confirmatory test arrangement and guidance |
TS EN 60695-11-5 EN 60695-11-5 IEC 60695-11-5 |
| Final Product | Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products (GWEPT) |
TS EN 60695-2-11 EN 60695-2-11 IEC 60695-2-11 |
| Luminaires |
Luminaires – Part 1: General requirements and tests Excluded clauses: Short-circuit protection PTI Photobiological Hazards Abnormal Circuit Conditions Resistance to Tracking |
EN 60598-1 IEC 60598-1 Excluded clauses: Sub-clause 4.26 Sub-clause 11.2 Sub-clause 4.24 Sub-clause 12.5.3 / Appendix C Sub-clause 13.4 |
| Luminaires |
Luminaires – Part 2: Particular Requirements –
Section One: Fixed General Purpose Luminaires Excluded clauses: Short-circuit protection PTI Photobiological Hazards Abnormal Circuit Conditions Resistance to Tracking |
EN 60598-2-1 IEC 60598-2-1 TS EN 60598-1 Excluded clauses: Sub-clause 4.26 Sub-clause 11.2 Sub-clause 4.24 Sub-clause 12.5.3 / Appendix C Sub-clause 13.4 |
| Medical electrical equipment |
Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance Excluded clauses Suitability for use in oxygen rich environment Defibrillation-proof parts Cathode ray tubes Hand transmitted vibration Protection against extreme hazards from unwanted and excessive radiation Fire prevention Temperature and overload controllers Protection of flammable anesthetic mixtures against ignition hazards |
TS EN 60601-1 EN 60601-1 IEC 60601-1 Excluded clauses Sub-clause:6.5 Sub-clause:8.5.5 Sub-clause:9.5.2 Sub-clause:9.6.3 Sub-clause 10 Sub-clause 11.2 Sub-clause 15.4.2 Appendix G |
| Safety requirements for electrical equipment for measurement, control, and laboratory use |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements Excluded clauses: Creepage Distances Protection against radiation, including laser sources, and against sonic and ultrasonic pressure Protection against liberated gases and substances, explosion and implosion |
TS EN 61010-1 EN 61010-1 Excluded clauses Sub clause:6.7.1.3 Sub-clause:12 Sub-clause:13 |
| Household and similar electrical appliances |
Household and similar electrical appliances - Safety - Part 1: General requirements Excluded clauses: Mechanical strength Construction Clearances, creepage distances and solid insulation Transient overvoltages Abnormal operation Radiation, toxicity and similar hazards Construction Software evaluation |
TS EN 60335-1 EN 60335-1 Excluded clauses: Sub-clause:21.1 Sub-clause:22.32 Sub-clause:29.2 Sub-clause:14 Sub-clause:19.11.4 Sub-clause:32 Sub-clause:22.46 Sub-clause:Annex-R |
| Maritime navigation and radiocommunication equipment and systems |
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results Excluded Clauses: Electromagnetic emission – Test methods and required test results Electromagnetic immunity – Test methods and required test results |
EN 60945 IEC 60945 Excluded Clauses: Sub-clause:9 Sub-clause:10 |
| Electrical equipment of machines | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
TS EN 60204-1 EN 60204-1 IEC 60204-1 |
| Empty enclosures | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
TS EN 62208 EN 62208 IEC 62208 |
| Enclosures |
Degrees of protection provided by enclosures (IP code) Excluded Clauses: IP X1, IP X2, and IP X9 |
EN 60529 IEC 60529 Excluded Clauses: IP X1, IP X2, and IP X9 |
| Enclosures | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
TS EN 62262 IEC 62262 EN 62262 |
Personal Protective Equipments
| Tested Materials / Products | Name of Test | Testing Method (National, International Standards, In-house Methods) |
|---|---|---|
| Life Jackets and Accessories | Physical Tests |
TS EN ISO 12402-7 Clause 4.1.6.3 Clause 4.1.6.4 Clause 4.11.1.2 (TS EN ISO 12402-2, TS EN ISO 12402-3, TS EN ISO 12402-4, TS EN ISO 12402-5) MSC.81 (70) Clause 2.1, Clause 2.2, Clause 2.3, Clause 2.4, Clause 2.6, Clause 2.7, Clause 2.8, Clause 2.9, Clause 2.10, Clause 2.11, Clause 10.3 |
| Life Jackets and Accessories | Physical Tests |
TS EN ISO 12402-8 Clause 5.2 Clause 5.4 Clause 5.5.2 Clause 5.9 Clause 5.10 Clause 5.11 (TS EN ISO 12402-2, TS EN ISO 12402-3, TS EN ISO 12402-4, TS EN ISO 12402-5) MSC.81 (70) Clause 2.1, Clause 2.2, Clause 2.3, Clause 2.4, Clause 2.6, Clause 2.7, Clause 2.8, Clause 2.9, Clause 2.10, Clause 2.11, Clause 10.3 |
| Life Jackets and Accessories | Physical Tests |
TS EN ISO 12402-9 (TS EN ISO 12402-2, TS EN ISO 12402-3, TS EN ISO 12402-4, TS EN ISO 12402-5) MSC.81 (70) Clause 2.1, Clause 2.2, Clause 2.3, Clause 2.4, Clause 2.6, Clause 2.7, Clause 2.8, Clause 2.9, Clause 2.10, Clause 2.11, Clause 10.3 |